Yeah, I have a couple sites with either a SyncPipe Deluxe or a SyncBox
on top powered separately and a SyncInjector with it's own Basic pipe at
the bottom to provide redundant timing to some 450 sectors.
I also have some 450 sectors each with their own Parasitic pipes because
they're far apart on the tower. And I get some strange GPS issues there
when it rains or there's heavy cloud cover. So I asked Forrest if it
would be OK to put a sync over power pulse through the Parasitic pipes.
He said no issues and I've bench tested it, so I'm going to add a
SyncInjector on those APs
On 6/19/2015 11:06 AM, Ken Hohhof wrote:
I have mostly switched to using the Syncbox12 instead of Parasitics.
It does have a Syncinjector port on it (which I haven’t had a use for).
*From:* Josh Luthman <mailto:j...@imaginenetworksllc.com>
*Sent:* Friday, June 19, 2015 10:48 AM
*To:* af@afmug.com <mailto:af@afmug.com>
*Subject:* Re: [AFMUG] 24v syncinjector wiring
1. From what I'm told you can do it. Just reverse the blue/brown
pairs. Sync pulse doesn't cause damage from what Forrest said.
2.
http://manuals.packetflux.com/index.php?page=using-a-syncpipe-parasitic-with-a-syncinjector
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Fri, Jun 19, 2015 at 11:45 AM, That One Guy /sarcasm
<thatoneguyst...@gmail.com <mailto:thatoneguyst...@gmail.com>> wrote:
I thought I had read these are both doable,
1. Can I power ubnt devices off these? what is the cross pinout?
and do I need to turn off the sync pulse on that port?
2. Can I use a syncpipe parasitic on the syncinjector? Isnt there
a particular cable pinout to do this?
--
If you only see yourself as part of the team but you don't see
your team as part of yourself you have already failed as part of
the team.