If Steve is wondering: The a lot of Meanwell PSU's have a screw to
adjust the output voltage. Usually it's to match the float voltage of
batteries, but if you don't have batteries you can crank it up all the way.
On 2/1/2016 4:29 PM, Josh Baird wrote:
We have gone back to sites and cranked the PSU's feeding the
SyncInjectors up to ~30V. We had numerous power and sync problems in
the cold weather when our PSU's were outputting ~25-26V (there was
~150ft of cable to the radio as well). We'll be rolling 48V at all
future sites.
On Mon, Feb 1, 2016 at 4:25 PM, Brandon Yuchasz
<[email protected] <mailto:[email protected]>> wrote:
I have run all mine at 24 volts all winter without issue. I did
not have any of the cold susceptible mac addresses however. My
only concern is if had a long power outage and batteries died
perhaps the epmp would have powered up the heaters and never got
to boot. It did not happen so it’s simply a theory on what could
still go wrong for me this winter. I do plan to step those
packetflux units up to 29.5v soon as possible.
Best regards,
Brandon Yuchasz
GogebicRange.net
www.gogebicrange.net <http://www.gogebicrange.net/>
*From:*Af [mailto:[email protected]
<mailto:[email protected]>] *On Behalf Of *Mike Hammett
*Sent:* Monday, February 01, 2016 3:04 PM
*To:* [email protected] <mailto:[email protected]>
*Subject:* Re: [AFMUG] Packetflux gigabit syncinjector force
connectorized epmp 24 V
Running them at 24v is what some of the commotion has been about
lately.
-----
Mike Hammett
Intelligent Computing Solutions <http://www.ics-il.com/>
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>
Midwest Internet Exchange <http://www.midwest-ix.com/>
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>
The Brothers WISP <http://www.thebrotherswisp.com/>
<https://www.facebook.com/thebrotherswisp>
<https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
------------------------------------------------------------------------
*From: *"That One Guy /sarcasm" <[email protected]
<mailto:[email protected]>>
*To: *[email protected] <mailto:[email protected]>
*Sent: *Monday, February 1, 2016 3:02:44 PM
*Subject: *[AFMUG] Packetflux gigabit syncinjector force
connectorized epmp 24 V
I have a site we will initially feed with an epmp force 110
(connectorized epmp) and serve two EPMPgps APs from it. To
conserver space, I want to just run all three radios off a gigabit
syncinjector, but the epmp connectorized is limited to 30 v.
Is there any issue running the EPMP gps APs on 24 volts?
--