Woulda been nice. Oh well.

This I think is another good example for a UGPS-like SyncPipe. Could I send a climber up to take the Parasitic pipe out and then throw on a SyncInjector at the bottom... sure. Burning a GigE SyncInjector for a 1 AP site though.

On 3/26/2016 6:42 PM, Forrest Christian (List Account) wrote:

I wouldn't recommend this. Mainly because it's going to unbalance the gigabit ethernet pairs and likely cause ethernet errors as the power consumption changes.

On Mar 26, 2016 7:15 AM, "George Skorup" <geo...@cbcast.com <mailto:geo...@cbcast.com>> wrote:

    Dumb question, probably best answered by Forrest. Say I have one
    of the newer universal Parasitic SyncPipes. Newer meaning Rev G+.
    Universal meaning you can use them on standard Canopy 30VDC POE
    and the stupid 320/430 pinout, since they tap only the two power
    pins that don't change. OK, so now say I take a GigE injector and
    configure a 450 AP to negotiate 1000BaseT. Will GigE work...
    "through" the Parasitic pipe? I know the 10/100 data pairs are
    passed straight through. Not sure about the other two pairs. Since
    it taps only two pins for power, I doubt there's any bonding going on.


Reply via email to