It happens on the regular 450 AP too. 1000Base-T does not work at all with GigE-APC-HV's in line. It is 100% the sync pulse causing the SS to clamp.

I won't speak for Chuck, but he sent me some stuff to test and it works. This was a yet unused 5GHz 450 AP at a site with ~220 feet of Shireen DC-1021. No SS on top. GigE PowerInjector+Sync fed with regulated 24v.

I have GigE-APCs on tons of POE and non-POE gigabit links *without a sync pulse* and they work perfectly fine. It would not surprise me if other brands of suppressors are doing the same thing because of the sync pulse. Maybe it takes the right conditions like temperature, power draw, etc. It's just immediately obvious with the GigE-APCs because they are moar betterer.

On 10/3/2016 12:45 PM, Forrest Christian (List Account) wrote:
We have very recently started getting a whole bunch of support queries which are from customers maintaining a gigabit link on a 450i. The link seems to come up at gig, then some time later drops back to 100Mb/s.

So far, we haven't nailed down a cause. Some seem to be related to the sync pulse, others are completely unaffected by this. Some seem to be related to the addition of a surge suppressor to the link (even a good quality one), some not. I'm even aware of quite a few cases where replacement of our gear with a stock cambium injector doesn't fix the problem - so I'm pretty comfortable in feeling that something other than our power injection equipment is the root cause.

The commonality of most of these are longer cable runs. All of the normal things have been tried (swapping cables, reterminating ends, validating cables, etc.). I also suspect that these are newer 450i's. (I'm not sure if we've seen this on a 450 or not).

So, what I'm hoping for from the list is to determine if this problem is widespread, and if there seems to be any relation to how old the 450i is, or a firmware version update, or something else so I can help fix this for my customers. Any information would be helpful.

--
*Forrest Christian* /CEO//, PacketFlux Technologies, Inc./
Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
forre...@imach.com <mailto:forre...@imach.com> | http://www.packetflux.com <http://www.packetflux.com/> <http://www.linkedin.com/in/fwchristian> <http://facebook.com/packetflux> <http://twitter.com/@packetflux>