I'm in the process of deploying something similar for our wired MDUs.  Each
MDU gets an SVLAN and each customer gets a CVLAN so there is a unique
CVLAN.SVLAN for each customer.  The SVLANs go into a VPLS connection back
to a Juniper BNG which dynamically creates the SVLAN/CVLANs, authenticates
the clients vs radius, and assigns DHCP.  I am disabling STP and filtering
it on customer ports.

On Wed, Jan 18, 2017 at 4:47 PM, Seth Mattinen <se...@rollernet.us> wrote:

> On 1/18/17 13:33, Josh Baird wrote:
>
>> In Cisco, this would be bpduguard.
>>
>
>
> Dare I suggest this is the perfect example of a use case for a proper
> metro ethernet switch with UNI/NNI port profiles.
>
> ~Seth
>



-- 

Carl Peterson

*PORT NETWORKS*

401 E Pratt St, Ste 2553

Baltimore, MD 21202

(410) 637-3707

Reply via email to