Only works for ring topologies, not tree.

On Sat, Jan 21, 2017 at 9:45 PM, Lewis Bergman <[email protected]>
wrote:

> G.8032 ERP always worked great for us.  Very fast convergence. I think
> every manufacturer has their own spin on it.
>
> On Jan 21, 2017 7:44 PM, "Mark Radabaugh" <[email protected]> wrote:
>
>> You want priority lowest on the switch that is 'most central' to your
>> network.
>>
>> For edge ports you probably want bpdu block or shutdown depending on how
>> you want to handle it.
>>
>> You really need to control bpdu's coming from your customers.  You don't
>> want a customer accidentally (or maliciously) taking control of your
>> topology.
>>
>> Mark Radabaugh
>> Amplex
>> 22690 Pemberville Rd
>> Luckey, OH 43447
>> 419-261-5996 <(419)%20261-5996>
>>
>> On Jan 21, 2017, at 4:30 PM, Mike Hammett <[email protected]> wrote:
>>
>> STP and RSTP really need to die. TRILL and SPB were invented because STP
>> and RSTP have some big deficiencies.
>>
>>
>>
>> -----
>> Mike Hammett
>> Intelligent Computing Solutions <http://www.ics-il.com/>
>> <https://www.facebook.com/ICSIL>
>> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb>
>> <https://www.linkedin.com/company/intelligent-computing-solutions>
>> <https://twitter.com/ICSIL>
>> Midwest Internet Exchange <http://www.midwest-ix.com/>
>> <https://www.facebook.com/mdwestix>
>> <https://www.linkedin.com/company/midwest-internet-exchange>
>> <https://twitter.com/mdwestix>
>> The Brothers WISP <http://www.thebrotherswisp.com/>
>> <https://www.facebook.com/thebrotherswisp>
>>
>>
>> <https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
>> ------------------------------
>> *From: *"Sterling Jacobson" <[email protected]>
>> *To: *[email protected]
>> *Sent: *Wednesday, January 18, 2017 2:02:39 PM
>> *Subject: *Re: [AFMUG] Switch expert help/advice
>>
>> Don’t all switches use some form of STP/RSTP Gino?
>>
>>
>>
>> I’m talking about best practices for a switch bank really.
>>
>>
>>
>> Do I set STP priority number lower than the default on the switch for the
>> ports going to other switches?
>>
>>
>>
>> And what is the term or feature that means ignore STP type packets from
>> that port (customer ports).
>>
>>
>>
>> I think I’m getting STP type topology changes every time a downstream
>> customer port has a up/down change etc.
>>
>>
>>
>> I don’t want those.
>>
>>
>>
>> *From:* Af [mailto:[email protected] <[email protected]>] *On
>> Behalf Of *Gino Villarini
>> *Sent:* Wednesday, January 18, 2017 2:00 AM
>> *To:* [email protected]
>> *Subject:* Re: [AFMUG] Switch expert help/advice
>>
>>
>>
>> Why are you using stp?
>>
>> On 1/18/17, 12:33 AM, "Af on behalf of Sterling Jacobson"
>>
>>
>>
>> *Gino Villarini*
>>
>> President
>>
>> Metro Office Park #18 Suite 304 Guaynabo, Puerto Rico 00968
>>
>> [image: cid:[email protected]]
>>
>> <[email protected] on behalf of [email protected]
>> <[email protected]%20on%20behalf%20of%[email protected]>> wrote:
>>
>> >Any of you guys work with switches a lot?
>> >
>> >I use banks of switches in my fiber, set up per neighborhood.
>> >
>> >But really they are all linked via fiber so it's pretty much like a
>> >datacenter.
>> >
>> >I'm using a few MPLS/VPLS tunnels to the switch banks.
>> >
>> >I'm having a real hard time tracking down a loop issue though.
>> >
>> >It's related to MikroTik lovely change in version 6.38 for STP/RSTP
>> >bridge stuff.
>> >
>> >My problem is with an IBM switch I don't know very well.
>> >
>> >I suspect I have settings wrong for STP/RSTP etc.
>> >
>> >The switches are a simple configuration of VLAN 1/default for customer
>> >traffic, then another VLAN for management from the device at their
>> >house/MDU.
>> >
>> >I pull out the VLAN management at the mikrotik and bridge it with an area
>> >wide L2 MPLS network.
>> >
>> >My problem is the IBM switches keep shutting down access to customer data
>> >or management or the other switches they are connected to.
>> >The crude method of recovery is reboot the switch.
>> >
>> >At the 'head' of the VPLS network I use an EOIP tunnel to a hosted
>> >mikrotik that hosts the Dude and a few other management VM's on that
>> >layer2 network.
>> >
>> >I'm regretting I did that and didn't create a more sophisticated routed
>> >management network.
>> >
>> >But the hosted mikrotik is complaining of loop packets and sometimes just
>> >goes wild and shuts down it's EOIP connecting interface for 60 seconds.
>> >I can't seem to find a way to tell it to NOT do that either, seems like
>> >it's built in to 6.38 no matter what Loop Protection I turn off or STP I
>> >disable.
>> >It's not like it's a lot of traffic, it's just seeing some BPDU or STP
>> >type packets and killing itself.
>> >
>> >What is the best practice for switches regarding RSTP/PVRST BDPU guards
>> >and STP root paths etc?
>> >
>> >The switches typically have two uplink ports going to the router or
>> >another switch, the rest are customer facing ports.
>>
>>

Reply via email to