Nice!  Common model of deployment especially with Juniper MX upstream …

> On Jan 18, 2017, at 5:54 PM, Carl Peterson <cpeter...@portnetworks.com> wrote:
> 
> I'm in the process of deploying something similar for our wired MDUs.  Each 
> MDU gets an SVLAN and each customer gets a CVLAN so there is a unique 
> CVLAN.SVLAN for each customer.  The SVLANs go into a VPLS connection back to 
> a Juniper BNG which dynamically creates the SVLAN/CVLANs, authenticates the 
> clients vs radius, and assigns DHCP.  I am disabling STP and filtering it on 
> customer ports.  
> 
> On Wed, Jan 18, 2017 at 4:47 PM, Seth Mattinen <se...@rollernet.us 
> <mailto:se...@rollernet.us>> wrote:
> On 1/18/17 13:33, Josh Baird wrote:
> In Cisco, this would be bpduguard.
> 
> 
> Dare I suggest this is the perfect example of a use case for a proper metro 
> ethernet switch with UNI/NNI port profiles.
> 
> ~Seth
> 
> 
> 
> -- 
> Carl Peterson
> 
> PORT NETWORKS
> 
> 401 E Pratt St, Ste 2553
> 
> Baltimore, MD 21202
> 
> (410) 637-3707 
> 