Fine tip marker is really the best

On Thu, Dec 28, 2017, 8:53 PM George Skorup <[email protected]>
wrote:

> For office/structure wiring, simple electrical wire number markers work
> fine. The kind you can get in booklets or on a dispenser like this:
> https://www.zoro.com/3m-wire-marker-tape-wdispenser-preprintd-std-0-9/i/G3472226/
> They're cheap enough to put two sets of numbers 3-5 feet apart at the ends
> in case you need to trim excess. Or one set and re-mark after you trim,
> punch down, terminate, whatever.
>
> I've had a Dymo 5200 for years now. It's great for tower cables, patch
> panels and all kinds of stuff. I put a "GPS" label on SyncPipes at sites
> using the vinyl industrial tape. Been there for years and none have faded
> or blown away. For cable labels, you want the 3/4" tape since it prints
> across the width. The problem I have with the shrink tube label is that we
> often mark what's what after we terminate and plug things in, so you'd need
> at least 1/2" to fit over an RJ45.
>
>
> On 12/28/2017 7:32 PM, Jeremy wrote:
>
> For temporary labeling we use colored electrical tape
>
> On Thu, Dec 28, 2017 at 4:01 PM, Jason Wilson <[email protected]>
> wrote:
>
>> This is what I use for my tower sites.
>> http://www.dymo.com/en-US/dymo-labeling-needs/wire-cable-labeling/wire-cable-labeling/ind-heat-shrink-tube-3-8-in
>>
>>
>> http://www.dymo.com/en-US/dymo-labeling-needs/wire-cable-labeling/wire-cable-labeling/rhino-industrial-5200-label-maker
>>
>> It will layout labels for just about any  rack, power panel you name it.
>> It was worth the price. The heat shrink labels have lasted 2 years in the
>> weather so far.
>>
>>
>>
>> On Dec 28, 2017 10:38 AM, "Jaime Solorza" <[email protected]>
>> wrote:
>>
>>> The markers I use from Home Depot hold up very....most of wiring goes
>>> through conduit at well sites
>>>
>>>
>>> Jaime Solorza
>>>
>>> On Dec 28, 2017 9:31 AM, "Lewis Bergman" <[email protected]>
>>> wrote:
>>>
>>>> I could ship you mine but your right, Without an ID toner there is a
>>>> lot of running back and forth.
>>>>
>>>> On Thu, Dec 28, 2017 at 10:25 AM Nate Burke <[email protected]> wrote:
>>>>
>>>>> I like the fast pull plan, but I'm probably going to be doing all the
>>>>> termination by myself, so that involves alot of running back and forth.  I
>>>>> don't have that fancy of a toner, just a simple (and cheap) telco one,
>>>>> which always seems to be able to narrow it down to about 4 cables in the
>>>>> bundle that all tone equally.  I like Chuck's Binary idea, maybe vertical
>>>>> and horizontal lines with a sharpie.
>>>>>
>>>>>
>>>>> On 12/28/2017 9:55 AM, Bill Prince wrote:
>>>>>
>>>>> I'm with Lewis on this one. We do bundle duplex/quad groups together,
>>>>> but we don't worry about individual cables. We use the ID plugs and a 
>>>>> toner
>>>>> to figure out which one is which. Labels fall off, and markers smear,
>>>>> especially when they're getting manhandled.
>>>>>
>>>>>
>>>>> bp
>>>>> <part15sbs{at}gmail{dot}com>
>>>>>
>>>>>
>>>>> On 12/28/2017 7:32 AM, Lewis Bergman wrote:
>>>>>
>>>>> Honestly, we just pull them all and tone them after. Seems just as
>>>>> fast. We have a Fluke cable tester that has 8 ID plugs and the probe tells
>>>>> you which one you touch so you can do 8 at once. At least I think that is
>>>>> how it works. Even if not toning is pretty fast way. We put a guy on each
>>>>> end and start toning and punching each end as they go.
>>>>>
>>>>> On Thu, Dec 28, 2017 at 9:25 AM Jaime Solorza <
>>>>> [email protected]> wrote:
>>>>>
>>>>>> These are the ones I use on panels and end devices most of the time
>>>>>> for SCADA projects.  Electricians use them as well when they pull wire 
>>>>>> for
>>>>>> us...once tested and certified, we make our heat shrink and non heat 
>>>>>> shrink
>>>>>> Brady ID labels never remove the original ones.  We reposition if
>>>>>> necessary..
>>>>>>
>>>>>>
>>>>>> https://www.homedepot.com/p/Ideal-Wire-Marker-Booklet-Legend-10-Pack-44-103/100118633
>>>>>>
>>>>>> Jaime Solorza
>>>>>>
>>>>>> On Dec 28, 2017 8:16 AM, "Jaime Solorza" <[email protected]>
>>>>>> wrote:
>>>>>>
>>>>>> Here you go... several ways to get it done..
>>>>>>
>>>>>> https://www.cableorganizer.com/cable-identification/
>>>>>> Jaime Solorza
>>>>>>
>>>>>> On Dec 28, 2017 8:12 AM, <[email protected]> wrote:
>>>>>>
>>>>>>> Sharpie works but is difficult to do well and rubs off.
>>>>>>> You could use strips of tape and sharpie to do a binary code.
>>>>>>> Tape, tape, sharpie, tape = 13
>>>>>>>
>>>>>>> -----Original Message----- From: Nate Burke Sent: Thursday, December
>>>>>>> 28, 2017 8:06 AM To: Animal Farm Subject: [AFMUG] Office Wire labeling
>>>>>>> I'm getting ready to pull some Cat5 into an office space, about 40
>>>>>>> drops.  What's the best way to label the cables as they are pulled 
>>>>>>> before
>>>>>>> they are dressed/punched.  Printing a label for each cable that's going 
>>>>>>> to
>>>>>>> get cut off as it's dressed into the patch panel seems wasteful.  
>>>>>>> Colored
>>>>>>> tape could work, but may get cumbersome with the combinations.  Is 
>>>>>>> writing
>>>>>>> the drop number on the jacket with a Sharpie the best way?
>>>>>>>
>>>>>>
>>>>>>
>>>>>
>
>

Reply via email to