I could ship you mine but your right, Without an ID toner there is a lot of
running back and forth.

On Thu, Dec 28, 2017 at 10:25 AM Nate Burke <[email protected]> wrote:

> I like the fast pull plan, but I'm probably going to be doing all the
> termination by myself, so that involves alot of running back and forth.  I
> don't have that fancy of a toner, just a simple (and cheap) telco one,
> which always seems to be able to narrow it down to about 4 cables in the
> bundle that all tone equally.  I like Chuck's Binary idea, maybe vertical
> and horizontal lines with a sharpie.
>
>
> On 12/28/2017 9:55 AM, Bill Prince wrote:
>
> I'm with Lewis on this one. We do bundle duplex/quad groups together, but
> we don't worry about individual cables. We use the ID plugs and a toner to
> figure out which one is which. Labels fall off, and markers smear,
> especially when they're getting manhandled.
>
>
> bp
> <part15sbs{at}gmail{dot}com>
>
>
> On 12/28/2017 7:32 AM, Lewis Bergman wrote:
>
> Honestly, we just pull them all and tone them after. Seems just as fast.
> We have a Fluke cable tester that has 8 ID plugs and the probe tells you
> which one you touch so you can do 8 at once. At least I think that is how
> it works. Even if not toning is pretty fast way. We put a guy on each end
> and start toning and punching each end as they go.
>
> On Thu, Dec 28, 2017 at 9:25 AM Jaime Solorza <[email protected]>
> wrote:
>
>> These are the ones I use on panels and end devices most of the time for
>> SCADA projects.  Electricians use them as well when they pull wire for
>> us...once tested and certified, we make our heat shrink and non heat shrink
>> Brady ID labels never remove the original ones.  We reposition if
>> necessary..
>>
>>
>> https://www.homedepot.com/p/Ideal-Wire-Marker-Booklet-Legend-10-Pack-44-103/100118633
>>
>> Jaime Solorza
>>
>> On Dec 28, 2017 8:16 AM, "Jaime Solorza" <[email protected]>
>> wrote:
>>
>> Here you go... several ways to get it done..
>>
>> https://www.cableorganizer.com/cable-identification/
>> Jaime Solorza
>>
>> On Dec 28, 2017 8:12 AM, <[email protected]> wrote:
>>
>>> Sharpie works but is difficult to do well and rubs off.
>>> You could use strips of tape and sharpie to do a binary code.
>>> Tape, tape, sharpie, tape = 13
>>>
>>> -----Original Message----- From: Nate Burke Sent: Thursday, December 28,
>>> 2017 8:06 AM To: Animal Farm Subject: [AFMUG] Office Wire labeling
>>> I'm getting ready to pull some Cat5 into an office space, about 40
>>> drops.  What's the best way to label the cables as they are pulled before
>>> they are dressed/punched.  Printing a label for each cable that's going to
>>> get cut off as it's dressed into the patch panel seems wasteful.  Colored
>>> tape could work, but may get cumbersome with the combinations.  Is writing
>>> the drop number on the jacket with a Sharpie the best way?
>>>
>>
>>
>

Reply via email to