The markers I use from Home Depot hold up very....most of wiring goes
through conduit at well sites


Jaime Solorza

On Dec 28, 2017 9:31 AM, "Lewis Bergman" <[email protected]> wrote:

> I could ship you mine but your right, Without an ID toner there is a lot
> of running back and forth.
>
> On Thu, Dec 28, 2017 at 10:25 AM Nate Burke <[email protected]> wrote:
>
>> I like the fast pull plan, but I'm probably going to be doing all the
>> termination by myself, so that involves alot of running back and forth.  I
>> don't have that fancy of a toner, just a simple (and cheap) telco one,
>> which always seems to be able to narrow it down to about 4 cables in the
>> bundle that all tone equally.  I like Chuck's Binary idea, maybe vertical
>> and horizontal lines with a sharpie.
>>
>>
>> On 12/28/2017 9:55 AM, Bill Prince wrote:
>>
>> I'm with Lewis on this one. We do bundle duplex/quad groups together, but
>> we don't worry about individual cables. We use the ID plugs and a toner to
>> figure out which one is which. Labels fall off, and markers smear,
>> especially when they're getting manhandled.
>>
>>
>> bp
>> <part15sbs{at}gmail{dot}com>
>>
>>
>> On 12/28/2017 7:32 AM, Lewis Bergman wrote:
>>
>> Honestly, we just pull them all and tone them after. Seems just as fast.
>> We have a Fluke cable tester that has 8 ID plugs and the probe tells you
>> which one you touch so you can do 8 at once. At least I think that is how
>> it works. Even if not toning is pretty fast way. We put a guy on each end
>> and start toning and punching each end as they go.
>>
>> On Thu, Dec 28, 2017 at 9:25 AM Jaime Solorza <[email protected]>
>> wrote:
>>
>>> These are the ones I use on panels and end devices most of the time for
>>> SCADA projects.  Electricians use them as well when they pull wire for
>>> us...once tested and certified, we make our heat shrink and non heat shrink
>>> Brady ID labels never remove the original ones.  We reposition if
>>> necessary..
>>>
>>> https://www.homedepot.com/p/Ideal-Wire-Marker-Booklet-
>>> Legend-10-Pack-44-103/100118633
>>>
>>> Jaime Solorza
>>>
>>> On Dec 28, 2017 8:16 AM, "Jaime Solorza" <[email protected]>
>>> wrote:
>>>
>>> Here you go... several ways to get it done..
>>>
>>> https://www.cableorganizer.com/cable-identification/
>>> Jaime Solorza
>>>
>>> On Dec 28, 2017 8:12 AM, <[email protected]> wrote:
>>>
>>>> Sharpie works but is difficult to do well and rubs off.
>>>> You could use strips of tape and sharpie to do a binary code.
>>>> Tape, tape, sharpie, tape = 13
>>>>
>>>> -----Original Message----- From: Nate Burke Sent: Thursday, December
>>>> 28, 2017 8:06 AM To: Animal Farm Subject: [AFMUG] Office Wire labeling
>>>> I'm getting ready to pull some Cat5 into an office space, about 40
>>>> drops.  What's the best way to label the cables as they are pulled before
>>>> they are dressed/punched.  Printing a label for each cable that's going to
>>>> get cut off as it's dressed into the patch panel seems wasteful.  Colored
>>>> tape could work, but may get cumbersome with the combinations.  Is writing
>>>> the drop number on the jacket with a Sharpie the best way?
>>>>
>>>
>>>
>>

Reply via email to