FYI,

I installed the gas tube version on a gigabit  Packetflux Powered Medusa
the other week and no go. The radio boots up for about 25 seconds, and then
shuts down.

On Wed, May 9, 2018 at 9:54 AM, <[email protected]> wrote:

> I am going to chase this down.  Only certain types of products have the
> issue it seems.
> I am going to try to add solid state to the gas tubes using a different
> design that eliminates the steering diodes.
> Seems like the steering diodes are causing the problem in some
> situations.
>
> *From:* George Skorup
> *Sent:* Wednesday, May 9, 2018 9:50 AM
> *To:* [email protected]
> *Subject:* Re: [AFMUG] mccowntech rack mount surge suppressor with Medusa
>
> No diodes, just gas-tube for large surge event suppression. Obviously not
> as much protection though. I'm seeing more CRC errors than I'm comfortable
> with on the cards with diodes. Rev G is definitely better though. I've
> broken the shield at various sites while testing to rule out any potential
> ground loop issues. Ran on battery. Etc. It's weird. Noise or something, I
> don't know.
>
> On 5/9/2018 10:32 AM, Steve Jones wrote:
>
> What's this gas tube product placement?
> I want to see these
>
> On Wed, May 9, 2018, 9:51 AM <[email protected]> wrote:
>
>> Thanks, yeah nothing fit well next to the thin pcbs.
>>
>> Odd, got some test results back from George yesterday.  Some types of
>> equipment has CRC errors with some of our surge suppressors.  Trying to
>> identify the bad combinations.  Good thing is that our gas tube only
>> products seem to be flawless with everything that people have tried them
>> on.
>>
>> -----Original Message-----
>> From: Matt
>> Sent: Wednesday, May 9, 2018 8:08 AM
>> To: [email protected]
>> Subject: Re: [AFMUG] mccowntech rack mount surge suppressor with Medusa
>>
>> Chuck,
>>
>> Like form factor of new arrestors much better.  Thicker PCB and RJ45
>> not as tall.  They do not fit well next to your last thin pcb version
>> though.  Did not care for the thin pcb and tall RJ45 at all.  Swapped
>> out 4 PxP450i APC arrestors to these 17 hours ago.  So far flawless
>> even at 1000base.  No errors at all.  This is with RackInjector,
>> Cambium Sync and very long cat-5 runs.  Time will tell but looks good
>> so far.
>>
>>
>>
>> On Wed, Apr 4, 2018 at 10:29 AM,  <[email protected]> wrote:
>> > Matt,
>> >
>> > I sent you a note off-list.  I would like to send you the gas tube
>> version
>> > to see if that fixes the issue.
>> >
>> > Inquiring minds want to know...
>> >
>> > -----Original Message----- From: Matt
>> > Sent: Wednesday, March 28, 2018 4:08 PM
>> > To: [email protected]
>> > Subject: Re: [AFMUG] mccowntech rack mount surge suppressor with Medusa
>> >
>> >> OK, so grounds are related to the problem.
>> >>
>> >> There may be something unusual with timing pulses on the power that is
>> >> causing the surge suppressor to fire.
>> >> Forrest would know much more than I about that.
>> >>
>> >> I honestly don’t know if anyone has tried my product with a Medusa
>> >> before.
>> >> I have a 100% gas tube version that may solve the problem.
>> >
>> >
>> > I am still having some troubles with PTP450i holding 1gbit ethernet
>> > even with Cambium sync.  Not near as bad with Cambium Sync though.
>> > Will these gas tube versions work any better?  Will they still keep
>> > equipment safe?
>>
>>
>


-- 
-- 
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>

Reply via email to