Gil

I know it works in the way you've proposed but I need to use the SETC in a
very bigger macro.

João Reginato
(61) 9911-55500


Em ter., 14 de nov. de 2023 às 17:49, João Reginato <jb.regin...@gmail.com>
escreveu:

> now with LCLC and CSECT. Same error
>
> João Reginato
> (61) 9911-55500
>
> Symbol   Type   Id     Address  Length   Owner Id Flags Alias-of
>                  HLASM R6.0  2023/11/14 17.46
> XYZ       SD 00000001 00000000 00000000             00
>
>
>
>
>                                      Page    3
>   Active Usings: None
>
>   Loc  Object Code    Addr1 Addr2  Stmt   Source Statement
>                  HLASM R6.0  2023/11/14 17.46
>                                       1          MACRO
>
>                                       2          ZERO  &N
>
>                                       3          LCLC  &REST
>
>                                       4 &REST    SETC  'SR    &N,&N'
>
>                                       5          &REST
>
>                                       6          MEND
>
> 000000                00000 00000     7 XYZ      CSECT
>
>                                       8          ZERO  15
>
>                                       9+         SR    15,15
>                                      01-00005
> ** ASMA057E Undefined operation code - 00005/SR    15,15
>
> ** ASMA435I Record 5 in JOAO.QWASM.JOB09578.D0000101.? on volume:
>
>                                      10          END
>
>
> Em ter., 14 de nov. de 2023 às 17:46, Paul Gilmartin <
> 00000014e0e4a59b-dmarc-requ...@listserv.uga.edu> escreveu:
>
>> On 11/14/23 13:28:09, João Reginato wrote:
>> > hi
>> > I can't see the error on this simple code.
>> > Can anyone help me pls?
>> >
>> > TIA
>> > João Reginato
>> > (+55 61) 9911-55500
>> >
>> >
>> >    Active Usings: None
>> >
>> >    Loc  Object Code    Addr1 Addr2  Stmt   Source Statement
>> >                   HLASM R6.0  2023/11/14 16.58
>> >                                        1          MACRO
>> >                                        2          ZERO  &N
>> >                                        3 &REST    SETC  'SR    &N,&N'
>> >                                        4          &REST
>> >                                        5          MEND
>> >                                        6          ZERO  15
>> >                                        7+         SR    15,15
>> >                                       01-00004
>> > ** ASMA057E Undefined operation code - 00004/SR    15,15
>> > ** ASMA435I Record 4 in JOAO.QWASM.JOB09574.D0000101.? on volume:
>> >.
>> I believe the SETC is unnecessary.  How a bout just:
>>           MACRO
>> &REST    ZERO  &N
>> &REST    SR    &N,&N
>>           MEND
>>
>>           START
>> L        ZERO  15
>>           END
>>
>> --
>> gil
>>
>