On Fri, 26 Nov 2004, Rich Adamson wrote: [SNIP]
> What if you have a single port T1/E1 card from digium? No decision to > be made really; you're going to sync from the other end if it goes > higher in the hierarchical chain. If the port goes to a box consider > lower in the chain, then the distant box should be configured to > accept clock sync. How about the following topology for a bit of discussion: Telco -> T100P -> * Server A -> IAX2 -> * Server B -> T100P -> PRI PBX In this case, we have Server A pulling timing from the telco, ensuring they are in Synch. On the other side of the IAX2 link, we have Server B generating timing onto the span for the PBX to listen to. T100P is set to emulate an NI-2 switch. Seems to work without much of a problem, as it should! ;) -- Vice President of N2Net, a New Age Consulting Service, Inc. Company http://www.n2net.net Where everything clicks into place! KP-216-121-ST _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users