> [EMAIL PROTECTED] wrote:
>> Hi,
>>
>> I have a Spectra Logic T50 and run about 50 jobs each night. The tape
>> library has 2 LTO3 drives. Lately it seems like at the beginning of the
>> night, one of the jobs will sit and and keep a drive waiting for a
>> volume
>> all night:
>>
>> 07-Dec 02:24 escabot-sd JobId 8280: Please mount Volume "000097LX" or
>> label a new
>> one for:
>>     Job:          espizarro.2007-12-07_02.00.55
>>     Storage:      "T50-Drive-1" (/dev/nst0)
>>     Pool:         Daily
>>     Media type:   LTO-3
>
> Was the volume being requested, 000097LX, already mounted on the other
> tape
> drive, nst1?  If so, it sounds like you're hitting the same glitch I ran
> into:
>
> http://bugs.bacula.org/view.php?id=1018
>

Yeah, seems to be the same problem. I haven't actually watched to see if
the other drive is requesting the tape at the same time, but I assumed
that it was something like that. Its also at the beginning of the jobs, so
that sounds right. I guess they don't have any ETA -- I'm also using
version 2.2.6.


--Marc

> --
> Frank Sweetser fs at wpi.edu  |  For every problem, there is a solution
> that
> WPI Senior Network Engineer   |  is simple, elegant, and wrong. - HL
> Mencken
>     GPG fingerprint = 6174 1257 129E 0D21 D8D4  E8A3 8E39 29E3 E2E8 8CEC
>
> !DSPAM:1,47595342206877771210147!
>
>



-------------------------------------------------------------------------
SF.Net email is sponsored by:
Check out the new SourceForge.net Marketplace.
It's the best place to buy or sell services for
just about anything Open Source.
http://sourceforge.net/services/buy/index.php
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to