[EMAIL PROTECTED] wrote:
> Hi,
> 
> I have a Spectra Logic T50 and run about 50 jobs each night. The tape
> library has 2 LTO3 drives. Lately it seems like at the beginning of the
> night, one of the jobs will sit and and keep a drive waiting for a volume
> all night:
> 
> 07-Dec 02:24 escabot-sd JobId 8280: Please mount Volume "000097LX" or
> label a new
> one for:
>     Job:          espizarro.2007-12-07_02.00.55
>     Storage:      "T50-Drive-1" (/dev/nst0)
>     Pool:         Daily
>     Media type:   LTO-3

Was the volume being requested, 000097LX, already mounted on the other tape
drive, nst1?  If so, it sounds like you're hitting the same glitch I ran into:

http://bugs.bacula.org/view.php?id=1018

-- 
Frank Sweetser fs at wpi.edu  |  For every problem, there is a solution that
WPI Senior Network Engineer   |  is simple, elegant, and wrong. - HL Mencken
    GPG fingerprint = 6174 1257 129E 0D21 D8D4  E8A3 8E39 29E3 E2E8 8CEC

-------------------------------------------------------------------------
SF.Net email is sponsored by:
Check out the new SourceForge.net Marketplace.
It's the best place to buy or sell services for
just about anything Open Source.
http://sourceforge.net/services/buy/index.php
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to