> On 10 Feb, 2017, at 12:05, Pete Heist <petehe...@gmail.com> wrote:
> 
> It means that both the ingress and egress have been redirected over the same 
> IFB device and QoS'd together.

Okay, I guessed as much but wanted to be sure.

I can’t think of any theoretical reason for these results.  Cake’s flow 
isolation should be robust enough to cope transparently with bidirectional 
traffic in half-duplex mode.  As you say, a C2D should easily be able to keep 
up, and at these modest rates I can even discount PCI bandwidth as a concern.  
So I might need to try to reproduce it here.

Does the problem go away if you use a wired link with the same setup otherwise? 
 Or is that inconvenient to try?  I have some ath9k equipped machines, but they 
would need to be set up.

 - Jonathan Morton

_______________________________________________
Cake mailing list
Cake@lists.bufferbloat.net
https://lists.bufferbloat.net/listinfo/cake

Reply via email to