Hi Jack,

I'm thinking that the ruby script 'adc16_init.rb' does not identify the
'--demux' parameter. I used the code at 'git://
github.com/david-macmahon/casper_adc16.git'. What can I do to set the
parameter?

Thank you


Sincerely,


*Vishwa Seneviratne*

*Graduate Student*

*Dept. of Electrical and Computer Engineering*
*University of Akron*

On Wed, Feb 3, 2016 at 11:02 AM, Vishwa Seneviratne <mp...@zips.uakron.edu>
wrote:

> Hi Jack,
>
> I did try all the combinations. The error remains the same.
>
> $ adc16_init.rb -v --demux=1 192.168.10.5 poly_design.bof
>
> /var/lib/gems/1.9.1/gems/adc16-0.3.6/bin/adc16_init.rb:40:in `<top
> (required)>': invalid option: --demux=2 (OptionParser::InvalidOption)
>
> from /usr/local/bin/adc16_init.rb:19:in `load'
>
> from /usr/local/bin/adc16_init.rb:19:in `<main>'
>
>
> Sincerely,
>
>
> *Vishwa Seneviratne*
>
> *Graduate Student*
>
> *Dept. of Electrical and Computer Engineering*
> *University of Akron*
>
> On Wed, Feb 3, 2016 at 2:25 AM, Jack Hickish <jackhick...@gmail.com>
> wrote:
>
>> Hi Vishwa,
>>
>> Is the syntax definitely -demux=1 andnot either --demux=1 or -d 1 ?
>>
>>
>> Jack
>>
>> On Wed, 3 Feb 2016, 12:39 a.m. Vishwa Seneviratne <mp...@zips.uakron.edu>
>> wrote:
>>
>>> Hi,
>>>
>>> I am working on how to work with different operating of the 'ADC16x250-8
>>> coax rev 2' for a very simple design to test how the ADC works. The design
>>> is compiled at an IP clock rate setting of 200MHz. My objective is to
>>> sample my input signal at higher sampling rate (preferably 400, 800 MHz).
>>>
>>> According to the user guide ''
>>> https://casper.berkeley.edu/wiki/images/4/4c/ADC16_user_guide.txt"; by
>>> setting the demux parameter I should be able to switch between different
>>> sampling rates. I get the following error.
>>>
>>> $ adc16_init.rb -v -demux=1 192.168.10.5 poly_design.bof
>>>
>>> /var/lib/gems/1.9.1/gems/adc16-0.3.6/bin/adc16_init.rb:40:in `<top
>>> (required)>': invalid option: -demux=2 (OptionParser::InvalidOption)
>>>
>>> from /usr/local/bin/adc16_init.rb:19:in `load'
>>>
>>> from /usr/local/bin/adc16_init.rb:19:in `<main>'
>>>
>>> When I don't pass the 'demux' parameter the ADC board get initialized to
>>> 8 analog inputs by default.
>>>
>>> How do I resolve this issue? or how can I set the ADC's to operate at
>>> different sampling rates?
>>>
>>> Thank you in advance
>>>
>>> Sincerely,
>>>
>>>
>>> *Vishwa Seneviratne*
>>>
>>> *Graduate Student*
>>>
>>> *Dept. of Electrical and Computer Engineering*
>>> *University of Akron*
>>>
>>
>

Reply via email to