On Sat, Mar 27, 2010 at 16:13, Markku Leiniö <[email protected]> wrote:
> Hi, my typical straightforward fix for those issues is
>
> int s0/1/0
> shut
> int s0/1/0.xx
> frame interface-dlci xxx
> int s0/1/0
> no shut
>
> This has to be done in quite many labs in Volume 1. I take it just as
> a good training for troubleshooting.


That exactly was the solution I used to fix this issue. Now, the
question is what exactly happened. Since I didn't want to use much of
Angel's time on the pod, I didn't look at R4, but I suspect it had
Inverse ARP active.

--
Marko Milivojevic - CCIE #18427