Thanks Markku, I'll have it mind on every Lab1 I work on :) Regards,
Angel. On Sat, Mar 27, 2010 at 12:15 PM, Marko Milivojevic <[email protected]>wrote: > On Sat, Mar 27, 2010 at 16:13, Markku Leiniö <[email protected]> > wrote: > > Hi, my typical straightforward fix for those issues is > > > > int s0/1/0 > > shut > > int s0/1/0.xx > > frame interface-dlci xxx > > int s0/1/0 > > no shut > > > > This has to be done in quite many labs in Volume 1. I take it just as > > a good training for troubleshooting. > > > That exactly was the solution I used to fix this issue. Now, the > question is what exactly happened. Since I didn't want to use much of > Angel's time on the pod, I didn't look at R4, but I suspect it had > Inverse ARP active. > > -- > Marko Milivojevic - CCIE #18427 > Senior Technical Instructor - IPexpert > > YES! We include 400 hours of REAL rack > time with our Blended Learning Solution! > > Mailto: [email protected] > Telephone: +1.810.326.1444 > Fax: +1.810.454.0130 > Web: http://www.ipexpert.com/ >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com