No, not for the switches. Setup there should be pretty straight-forward.

--
Marko Milivojevic - CCIE #18427
Senior Technical Instructor - IPexpert

FREE CCIE training: http://bit.ly/vLecture

Mailto: [email protected]
Telephone: +1.810.326.1444
Web: http://www.ipexpert.com/

On Sat, Nov 13, 2010 at 12:13, Jay Taylor <[email protected]> wrote:
> Yea, I know there's some 'magic' going on behind the scenes and we only see
> what they want us to see as far as topology goes so I opened a ticket with
> support about it.
>
> On Sat, Nov 13, 2010 at 12:12 PM, Jason Maynard <[email protected]>
> wrote:
>>
>> Hey Jay,
>>
>>
>>
>> I am pretty sure I that I have seen this as well some time ago.
>>
>>
>>
>> Not sure what it the problem was but I do know my configuration was
>> correct so I just moved on
>>
>>
>>
>> Not sure if this helps
>>
>>
>>
>> From: [email protected]
>> [mailto:[email protected]] On Behalf Of Jay Taylor
>> Sent: November-13-10 11:28 AM
>> To: CCIE OSL
>>
>> Subject: [OSL | CCIE_RS] Proctorlabs hardware issue?
>>
>>
>>
>> I'm having an issue where whichever port I add last to an etherchannel
>> between Cat1 and Cat2 will continually bounce. Configuration looks correct;
>> is this a hardware issue?
>>
>> Cat1:
>>
>> interface FastEthernet0/23
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>  channel-group 12 mode desirable
>> !
>> interface FastEthernet0/24
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>  channel-group 12 mode desirable
>> !
>> interface Port-channel12
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>
>>
>> Cat1(config)#do sh eth sum
>> Flags:  D - down        P - bundled in port-channel
>>         I - stand-alone s - suspended
>>         H - Hot-standby (LACP only)
>>         R - Layer3      S - Layer2
>>         U - in use      f - failed to allocate aggregator
>>
>>         M - not in use, minimum links not met
>>         u - unsuitable for bundling
>>         w - waiting to be aggregated
>>         d - default port
>>
>>
>> Number of channel-groups in use: 1
>> Number of aggregators:           1
>>
>> Group  Port-channel  Protocol    Ports
>>
>> ------+-------------+-----------+-----------------------------------------------
>> 12     Po12(SU)        PAgP      Fa0/23(P)   Fa0/24(P)
>>
>>
>> Cat2:
>>
>> interface FastEthernet0/23
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>  channel-group 12 mode desirable
>> !
>> interface FastEthernet0/24
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>  channel-group 12 mode desirable
>> !
>> interface Port-channel12
>>  switchport trunk encapsulation dot1q
>>  switchport mode trunk
>>
>>
>> Cat2(config)#do sh eth sum
>> Flags:  D - down        P - bundled in port-channel
>>         I - stand-alone s - suspended
>>         H - Hot-standby (LACP only)
>>         R - Layer3      S - Layer2
>>         U - in use      f - failed to allocate aggregator
>>
>>         M - not in use, minimum links not met
>>         u - unsuitable for bundling
>>         w - waiting to be aggregated
>>         d - default port
>>
>>
>> Number of channel-groups in use: 3
>> Number of aggregators:           3
>>
>> Group  Port-channel  Protocol    Ports
>>
>> ------+-------------+-----------+-----------------------------------------------
>> 12     Po12(SU)        PAgP      Fa0/23(P)   Fa0/24(P)
>> 23     Po23(SU)        LACP      Fa0/19(P)   Fa0/20(P)
>> 24     Po24(SU)        LACP      Fa0/21(P)   Fa0/22(P)
>>
>
>
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please
> visit www.ipexpert.com
>
>
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to