-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Dear Arko,

could you not try MAD with the two different data sets?
Otherwise you can check the strength of the anomalous signal for both
sets separately (I am sure pointless prints the anomalous CC over
resolution shell) and after merging them.
If the signal increases, use the merged data set for SAD, it it does
not, use them separately (but then you call it MAD...).

Tim

On 01/18/2012 12:03 PM, arka chakraborty wrote:
> Hi all,
> 
> I have two datasets, both CO SAD data, one collected at  CO anomalous
> wavelength at synchroton and the other at home source. I wish to combine
> these two data-sets and use for SAD phasing. Can anyone suggest how this
> can be done?
> 
> Regards,
> 
> ARKO
> 

- -- 
- --
Dr Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

GPG Key ID = A46BEE1A

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.10 (GNU/Linux)
Comment: Using GnuPG with Mozilla - http://enigmail.mozdev.org/

iD8DBQFPFqgcUxlJ7aRr7hoRAvTcAKCYRK3tWncS3s3WkCbRCylpWciZigCg8UG5
h7oLvHACutcAvbnBm4jknOs=
=az8S
-----END PGP SIGNATURE-----

Reply via email to