Qs
1) Why do you want to limit your data?
Most applications allow you to only use a specified sub-set - see GUI tasks
for "resolution limits".
In general you may want to run moleculer replacement or exptl phasing at a
limited resolution, but for refinenement or phase extension it is good to
use the whole range..
Eleanor
On Mar 19 2012, Abd Ghani Abd Aziz wrote:
hello everyone,
I am new in this bulletin board. I would like to know on how to cut my
resolution in my datasets that have been processed/produced in diamond
light source. In my processed directory, I found there are 3 files
(free.mtz, scaled.sca and unmerged.sca). May I know which one can be used
to cut my data that was diffracted to 1.5A? Cheers
regards
Abd Ghani
The University of Sheffield
--
Professor Eleanor Dodson
YSNL, Dept of Chemistry
University of York
Heslington YO10 5YW
tel: 00 44 1904 328259
Fax: 00 44 1904 328266