X2 10GBASE-SR :@ both ends

 
Rgds
Harry
 
Harry Hambi BEng(Hons)  MIET  Rsgb


-----Original Message-----
From: cisco-nsp [mailto:[email protected]] On Behalf Of Tom Hill
Sent: 15 October 2014 15:53
To: [email protected]
Subject: Re: [c-nsp] Optics

On 15/10/14 15:45, Harry Hambi - Atos wrote:
> Oct 15 14:39:14.024: %SFF8472-5-THRESHOLD_VIOLATION: Te2/0/1: Rx power high 
> warning; Operating value
> :  -1.8 dBm, Threshold value:  -2.0 dBm.
> Does the message suggest a faulty optic?.

No, it means that you're receiving too much light from the other side
(relative to the optic's threshold for light power received).

What type of optic is on either end? 10GBASE-LR/SR/ER?

-- 
Tom
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to