Olden,

A couple of things to try before opening a TAC case:

1.  show modules,  is the module recognized
2.  show test <mod#>,  what are the results, any failures
3.  reseat the module,  what are the console messages during this reseat
4. if all are still failures, verfiry a different slot in the chasis

Joe

Olden Pieterse wrote:

> Hi there
>
> Just quickly a question : I have a 6509 with a 48port ethernet card in it .
> On the front the status lights are orange
> If I do a show module x   , then I get a status==other , all the rest are ok
> .
> I have enabled the module , put the power on and the works !
>
> Is there anything else I can do to revive this module or can I safely assume
> its going to be good as a door stopper/paper weight ?
>
> Cheers
>
>                           Olden Pieterse
>                MCP , CCNA , BCMSN , BSCN , BCRAN
> Brainbench Certified CISCO Network Implementation Specialist
>                       Technical Consultant
> Mobile : +27 82 410 8621
>
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]