Hello, I'm currently looking to run multimode 50 micron 1300 nm fiber from building to building. Then once at each building the fiber will be terminated. From the termination point the fiber is going into a Cisco 2950-G 48 w/ 1000BASE-LX GBIC on both sides. From what I've read I need a fiber optic mode conditioning patch cables to go from the termination point to the Cisco switches. This is because it is running multimode between the buildings and the Cisco switch runs at single mode. Problem lies in that the optic mode conditioning patch cables come only in 62.5 micron cables. Has anyone had experience with this? Is the 62.5 micron going to cause a problem with the 50 micron between buildings? Any input/feedback would be appreciated.
Mode Conditioning Example: http://www.l-com.com/content/ResourceCenter/Tips/pages/fiber_06.htm Thanks!!! Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=72260&t=72260 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]