Why don't you just get multimode GBICs? Thanks,
Zsombor At 07:43 PM 7/14/2003 +0000, Schlotterer, Matthew wrote: >Hello, > >I'm currently looking to run multimode 50 micron 1300 nm fiber from building >to building. Then once at each building the fiber will be terminated. From >the termination point the fiber is going into a Cisco 2950-G 48 w/ >1000BASE-LX GBIC on both sides. From what I've read I need a fiber optic >mode conditioning patch cables to go from the termination point to the Cisco >switches. This is because it is running multimode between the buildings and >the Cisco switch runs at single mode. Problem lies in that the optic mode >conditioning patch cables come only in 62.5 micron cables. Has anyone had >experience with this? Is the 62.5 micron going to cause a problem with the >50 micron between buildings? Any input/feedback would be appreciated. > >Mode Conditioning Example: >http://www.l-com.com/content/ResourceCenter/Tips/pages/fiber_06.htm > >Thanks!!! Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=72269&t=72260 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]