If I am not mistaken... port 3/19 is your culprit.. -Sal
Walker, James - Is wrote: > > Dave, > > Blade 3 is bad. Open a TAC case, if you have support, and get > the blade > replaced. > > Jim > > -----Original Message----- > From: MADMAN [mailto:[EMAIL PROTECTED] > Sent: Tuesday, July 29, 2003 3:49 PM > To: [EMAIL PROTECTED] > Subject: 6500 10/100 line card COIL numbering [7:73194] > > > Hi, > > I have a customer whose 6500 switch seing this error: > > %SYS-3-SYS_LCPERR3:Module 3: Coil 1 Port 7: stuck 3 > > Does anyone know if the COILs start with number 0 or 1? I > know there > is 1 COIL per 12 ports and 1 Pinnacle ASIC per 4 COILs bt I can > not find > anywhere how the COILs are numbered. I am trying to identify > the > suspect ports but can't find the numbering scheme anywhere!! > > Thanks > > Dave > -- > David Madland > CCIE# 2016 > Sr. Network Engineer > Qwest Communications > 612-664-3367 > > "Government can do something for the people only in proportion > as it > can do something to the people." -- Thomas Jefferson > > Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=73240&t=73194 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]