If I am not mistaken... port 3/19 is your culprit..

-Sal


Walker, James - Is wrote:
> 
> Dave,
> 
> Blade 3 is bad. Open a TAC case, if you have support, and get
> the blade
> replaced.
> 
> Jim
> 
> -----Original Message-----
> From: MADMAN [mailto:[EMAIL PROTECTED]
> Sent: Tuesday, July 29, 2003 3:49 PM
> To: [EMAIL PROTECTED]
> Subject: 6500 10/100 line card COIL numbering [7:73194]
> 
> 
> Hi,
> 
>    I have a customer whose 6500 switch seing this error:
> 
> %SYS-3-SYS_LCPERR3:Module 3: Coil 1 Port 7: stuck 3
> 
>    Does anyone know if the COILs start with number 0 or 1?  I
> know there
> is 1 COIL per 12 ports and 1 Pinnacle ASIC per 4 COILs bt I can
> not find
> anywhere how the COILs are numbered.  I am trying to identify
> the
> suspect ports but can't find the numbering scheme anywhere!!
> 
>    Thanks
> 
>    Dave
> -- 
> David Madland
> CCIE# 2016
> Sr. Network Engineer
> Qwest Communications
> 612-664-3367
> 
> "Government can do something for the people only in proportion
> as it
> can do something to the people." -- Thomas Jefferson
> 
> 




Message Posted at: