On 8 Oct 2000 20:04:29 -0400, FRS <[EMAIL PROTECTED]> wrote:
:Just messing around with a router did a show int token 0 command says:
:Interface up, Line protocol down.
:When you issue the no shut command on the interface it still says Interface
:up, Line protocol down. Why is this?
The shutdown command will give a "Interface is administratively down"
response to show commands.
Essentially, the interface is not happy with the token ring network.
Could be any of
* Physically not connected
* ring speed mismatch
* ring speed not set
* cable problem
etc.
--
Jay Hennigan - Network Administration - [EMAIL PROTECTED]
NetLojix Communications, Inc. NASDAQ: NETX - http://www.netlojix.com/
WestNet: Connecting you to the planet. 805 884-6323
**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html