Jay,
I issued a no shutdown command ... is the state not supposed to be UP, UP
now?
"Jay Hennigan" <[EMAIL PROTECTED]> wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> On 8 Oct 2000 20:04:29 -0400, FRS <[EMAIL PROTECTED]> wrote:
>
> :Just messing around with a router did a show int token 0 command says:
> :Interface up, Line protocol down.
> :When you issue the no shut command on the interface it still says
Interface
> :up, Line protocol down. Why is this?
>
> The shutdown command will give a "Interface is administratively down"
> response to show commands.
>
> Essentially, the interface is not happy with the token ring network.
> Could be any of
>
> * Physically not connected
> * ring speed mismatch
> * ring speed not set
> * cable problem
>
> etc.
>
> --
> Jay Hennigan - Network Administration - [EMAIL PROTECTED]
> NetLojix Communications, Inc. NASDAQ: NETX - http://www.netlojix.com/
> WestNet: Connecting you to the planet. 805 884-6323
>
> **NOTE: New CCNA/CCDA List has been formed. For more information go to
> http://www.groupstudy.com/list/Associates.html
> _________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
>
**NOTE: New CCNA/CCDA List has been formed. For more information go to
http://www.groupstudy.com/list/Associates.html
_________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]