nope you're right!   :-)

3000's can't do the DCE thing.  Got one here hooked up to a 4000.  Same prob
but of course for me it's ok as the 4000 does dce.

Guess you need a 3rd router in the middle!

any excuse to buy another router is good for me.  (unless one of the gurus
here can concoct a special cable for you???)

Kevin Wigle

----- Original Message -----
From: "Nathan Cruz" 
To: 
Sent: Monday, 23 April, 2001 19:19
Subject: Can a 3104 serial interface provide clocking? [7:1656]


> I am trying to hook up two 3104's back to back but when I try to put in
clock
> 64000 I get the error msg. "Not allowed on DTE interface". When in fact
the
> sh
> controller command shows that it is a dce cable attached. Any help would
be
> appreciated. Thanks.
>
> Nathan
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=1659&t=1656
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]