If I am using a 2522 as a frame relay switch, can its A/S serial ports be
configured as DCE interfaces and be connected to other router DTE interfaces
using a 60pin-60pin crossover cables?  I am trying to setup a fram relay
switch with more than 2 routers participate (excluding the frame relay
switch router itself) so that I can create a hub router....  Any other
suggestion for this configuration?  Thanks.







""Fischer Reinhold""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi Thomas,
>
> i think it is not possible what you are trying to accomplish.
> You need one Router with at least two serial interfaces dedicated
> as the frame relay switch. So you need at least 3 Routers with
> serial interfaces to practice frame relay.
>
> Others please correct me if there is a trick to do it with two routers.
>
> Greetings
>
> Reinhold
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]