Try the following
timeout xlate 0:05:00 conn 0:05:00 half-closed 0:05:00 udp 0:01:00
timeout rpc 0:05:00 h323 0:05:00
timeout uauth 0:05:00 absolute uauth 0:04:00 inactivity

""Dennis Laganiere""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> I've got a PIX 513 that went into production a few weeks ago.  It was
> running fine for a while, and one day we lost internet connectivity inside
> my network.
>
> I tested for a few minutes and could get out from the DMZ, but not from
> inside.  My partner reset the PIX and connectivity came back.  This
repeated
> itself a few days later.  Yesterday it happened twice.
>
> I obviously want to do something besides resetting it after each failure,
> but I'm not sure where to start.  I looked through the CCO and didn't find
> any reference to a problem like mine.
>
> Any thoughts before I call the TAC?
>
> Let me know...
>
> --- Dennis
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=2131&t=2128
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to