If traffic shaping, do both sides match?    Are you doing any FRF.12
fragmentation?   Are you sure the traffic shaping paramaters are OK?  I have
a feeling this is it.  Make sure both sides match.


""Paul Jin""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi Alex,
>
> This site has another router connection back to the hub so this PVC is not
> being used at this moment except for testing.
>
> I have no fecn/becns.  I have the CIR set at 128K on the network portion.
>
> No discards within the cloud.  in fact, within the network, it is
> around 70 ms between stratacom to stratacom.  But between the router
> to router ping, it is very abnormally high.
>
> The hub site has other PVCs exiting to other routers and they all
> work ok.  Just this particular one.
>
> It seems that something locally must be changed.  Bad thing is I have to
> rely on many intermediaries to get answers and get things done.
>
> Paul




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26328&t=26263
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]