The wan provider maps the DLCI to the IP of the FR switch at the opposite
end through special tables..  Furthermore, the Frame Relay header is stipped
off when entering the cloud and travels around via regualr IP or ATM, etc.
The FR header is then put back on once it reached the opposite FR switch.
They police your speed with CAR.


""]hsan Turkmen""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hi..
> Assume that I have several routers attached to a "FR Cloud" and  they are
> already communicating with each other. Now, one of you (who reads this
> subject) wants to build up a new connection between one of his routers and
> mine. Since there is a common network between us, each router attached to
> that cloud has to have a unique identifier. Using this identifier, anybody
> should be able to set-up a PVC or a SVC to another persons router (if he
is
> granted,of course) anytime.
>
> Now , here is (are) the question(s).*****  I have not seen such an
> identifier during the configuration of FR circuits  *****. Don't tell me
> that DLCI is the identifier, because it has no global significance, but
just
> a local parameter. In this case, how is a FR packet switched inside this
> common FR cloud.? Don't we have to worry about configuring PVC s, because
> this is (is it really) done by Telco?. If so, how do we set up SVCs then?
> What kind of a header does a FR packet have. How does a FR switch tell my
> packet from those of others.?
>
> I would very much appreciate your enlightment . Just give me a clue, no
> details needed. Thanks in advance.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26847&t=26819
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to