I have a lab setup as follows: 2 2500 series routers connected to a 2900 switch.
Router1 E0 192.168.1.1 255.255.255.0 Router 2 E0 192.168.2.1 255.255.255.0 Switch IP 192.168.1.3 255.255.255.0 I can ping and telnet to Router 1 and the switch. I can not ping Router2. When I telnet I receive this error message(Cam't open connection to host on port 23, a socket operation was attempted to an unreachable host) I console into Router 2 and E0 looks fine with ip ans it states it is administrately up. Any suggestions? Thanks, James Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=27695&t=27695 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]