this news will surely disappoint the woman who posted the question. If
memory serves,she works for a company that probably does not have 12xxx's in
their lineup

Chuck

""MADMAN""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Yes I have since you pointed that out.  Know what it means to
> ASSume!!  It is a 12000 series only feature at this point.
>
>   Dave
>
> Chuck wrote:
> >
> > according to the information in the link, this feature is supported only
on
> > the 12000 series. Anyone checked to see if the feature has been migrated
> > down to other platforms as newer IOS's are released?
> >
> > ""MADMAN""  wrote in message
> > [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> > > You want to get fancy you can try multilink frame relay:
> > >
> > >
> >
>
http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120
> > limit/120s/120s17/17s_mfr.htm
> > >
> > >   Then again if you want it simple and to work do what Patrick aluded
> > > to, enable CEF and on the interface choose your favorite switching
> > > mechanism, per packet or per destination.
> > >
> > >   Dave
> > >
> > > Patrick Ramsey wrote:
> > > >
> > > > well you wouldn't really "bind" them...but, if you were using a
routing
> > > > protocol such as ospf, then it could round robin packets for you.
> > > >
> > > > -Patrick
> > > >
> > > > >>> beth  02/19/02 10:34AM >>>
> > > > I have several 256k frame relay circuits some coming back to same
host
> > > > circuit
> > > > my question is , is there anyway to way to bind a couple of these on
a
> > > router
> > > > to increase bandwidth to 512k??
> > > > >>>>>>>>>>>>>  Confidentiality Disclaimer    This email and any
files
> > > transmitted with it may contain confidential and
> > > > /or proprietary information in the possession of WellStar Health
> System,
> > > > Inc. ("WellStar") and is intended only for the individual or entity
to
> > whom
> > > > addressed.  This email may contain information that is held to be
> > > > privileged, confidential and exempt from disclosure under applicable
> > law.
> > > If
> > > > the reader of this message is not the intended recipient, you are
> hereby
> > > > notified that any unauthorized access, dissemination, distribution
or
> > > > copying of any information from this email is strictly prohibited,
and
> > may
> > > > subject you to criminal and/or civil liability. If you have received
> > this
> > > > email in error, please notify the sender by reply email and then
delete
> > > this
> > > > email and its attachments from your computer. Thank you.
> > > >
> > > > ================================================================
> > > --
> > > David Madland
> > > Sr. Network Engineer
> > > CCIE# 2016
> > > Qwest Communications Int. Inc.
> > > [EMAIL PROTECTED]
> > > 612-664-3367
> > >
> > > "Emotion should reflect reason not guide it"
> --
> David Madland
> Sr. Network Engineer
> CCIE# 2016
> Qwest Communications Int. Inc.
> [EMAIL PROTECTED]
> 612-664-3367
>
> "Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=36034&t=35854
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html