Also...I have tested the wiring(basic tester...no NEXT/FEXT or other
factors...but lengths of cable are under 50ft) and replaced patch
cables...still no luck. Dain.

""Dain Deutschman""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hello Everyone,
>
> I have a Cat2950 in a small office throwing up thousands of CRCs, input
> errors and several runts on the port connected to the server. Clients are
> getting disconnected and database on server is constantly having to be
> repaired. The errors always follow the server no matter which port I move
it
> to. Have replaced NIC in server and a few key Wkst. Have also updated the
> NIC drivers. ( Win2000 w/3C905C-TX-M Nics ). I have forced speed and
duplex
> settings and disabled spanning-tree. I'm suspecting dirty power...but it
is
> connected to a UPS ( that only has limited EMI/RFI Filtering ). I connect
a
> 3Com unmanaged 8 port switch to the key clients and the server...no more
> problems. Any ideas?!? It's driving me nuts! Thanks in advance...
> --
> Dain Deutschman
> CNA, MCP, CCNA
> Data Communications Manager
> New Star Sales and Service, Inc.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=51426&t=51419
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]