Also...I have tested the wiring(basic tester...no NEXT/FEXT or other factors...but lengths of cable are under 50ft) and replaced patch cables...still no luck. Dain.
""Dain Deutschman"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > Hello Everyone, > > I have a Cat2950 in a small office throwing up thousands of CRCs, input > errors and several runts on the port connected to the server. Clients are > getting disconnected and database on server is constantly having to be > repaired. The errors always follow the server no matter which port I move it > to. Have replaced NIC in server and a few key Wkst. Have also updated the > NIC drivers. ( Win2000 w/3C905C-TX-M Nics ). I have forced speed and duplex > settings and disabled spanning-tree. I'm suspecting dirty power...but it is > connected to a UPS ( that only has limited EMI/RFI Filtering ). I connect a > 3Com unmanaged 8 port switch to the key clients and the server...no more > problems. Any ideas?!? It's driving me nuts! Thanks in advance... > -- > Dain Deutschman > CNA, MCP, CCNA > Data Communications Manager > New Star Sales and Service, Inc. Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=51426&t=51419 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]