The physical interface cannot be used as an active
connection if the sub-interfaces
are configured and used, I believe...

The below might be bettter...
>
> int serial 0
> encap frame-relay
> no shut

> int serial 0.10 multi
> no shut
> ip address  x.x.x.x
> frame-relay map ip x.x.x.x 17


Larry Letterman
Network Engineer
Cisco Systems

> Hi Again ,
> A new small query on frame-relay itself.
> Is the config below valid and can it  be used having both
Multipoint on main
> interface and poin-to-point sub interface simutaneusly.
>
> int serial 0
> encap frame-relay
> ip address
>
> frame-relay interface-dlci 16
>
> int serial 0/0.2 multi
> ip address
> frame-relay map  17
>
> Does such conguration can work or the Muti access config
on main interface
> will afffect the sub interfaces connections also.
> What implications the above design has or all 3
connections can be made to
> work
> any help will be appreciated.
> Thanx in advance
[EMAIL PROTECTED]




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=63485&t=63460
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to