I use the Loos RT 10 to tension my rig.....our rigs are different so
numbers may be irrelevant.....without the gauge, I would be guessing and
from experience, that's not a very accurate way to know how much tension
is on the shrouds.
If you have rod rigging, the tension should never exceed 20% of the
breaking strength of the rod. My uppers are tensioned around 15% ,
lowers around 13% of the rod's breaking strength.
Rob Abbott
AZURA
C&C 32 - 84
Halifax, N.S.