mobuchowski commented on code in PR #39513:
URL: https://github.com/apache/airflow/pull/39513#discussion_r1598114661


##########
tests/providers/openlineage/plugins/test_listener.py:
##########
@@ -33,10 +33,20 @@
 from airflow.providers.openlineage.plugins.listener import OpenLineageListener
 from airflow.providers.openlineage.utils.selective_enable import 
disable_lineage, enable_lineage
 from airflow.utils.state import State
+from tests.test_utils.compat import AIRFLOW_V_2_10_PLUS
 from tests.test_utils.config import conf_vars
 
 pytestmark = pytest.mark.db_test
 
+EXPECTED_TRY_NUMBER_1 = 1 if AIRFLOW_V_2_10_PLUS else 0

Review Comment:
   @kacpermuda is right - we had to work around `try_number` handling before, 
now we don't - but still have to correct previous behavior for Airflow < 2.10.



-- 
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.

To unsubscribe, e-mail: commits-unsubscr...@airflow.apache.org

For queries about this service, please contact Infrastructure at:
us...@infra.apache.org

Reply via email to