On Tuesday 30 June 2009, Steve Chen wrote: > Can you try > > aplay -D hw:0,1 r441_c2.wav > > If you see something like > > Warning: rate is not accurate (requested = 44100Hz, got = 48000Hz) > please, try the plug plugin > > That means McBSP/AIC33 are not setup to handle sample rate of 44.1K > directly. The sample rates are covered by software. The problem is > likely in the area of rate conversion.
And ... seeking someone who has a bit of spare time, a DM6446 EVM, and interest in solving it: that EVM can switch audio clocking at runtime, among six different sample rates (of which those are two). So it would be interesting to get that working. :) > If you don't see the warning, McBSP/AIC33 is setup to handle 44.1K > directly. You man want to check with clock settings (make sure AIC33 is > setup as the master). _______________________________________________ Davinci-linux-open-source mailing list Davinci-linux-open-source@linux.davincidsp.com http://linux.davincidsp.com/mailman/listinfo/davinci-linux-open-source