I had a quick question on the connect timeout...
The connect timeout supplied to connectors is in the unit of seconds, and it
appears the minimum value you can use is 1 second (
AbstractIoConnector.setConnectTimeout() in the case of the trunk).  Is this
by design?  I can see cases where one needs to have a shorter connect
timeout, but it seems it is not possible today.  One solution might be to
use ConnectFuture.join() with a timeout, but that works only if you want to
block until it times out...

It also seems that this minimum timeout value is somewhat tied to the
timeout value used in the select() loop in the connector, which is hard
coded to be 1 second.  Would it be a good idea to support connect timeout
values in milliseconds, and make it shorter than 1 second?

Thanks,
Sangjin