On 27/11/13 13:55, Sébastien Bourdeauducq wrote: > Hi, > > On 11/27/2013 01:44 PM, Adrian Byszuk wrote: >> With the soc-mixxeo-ports23 bitstream I get something like this in console >> >> when connecting to port HDMI3: >> dvisampler1: PLL locked >> IDELAY busy timeout >> dvisampler1: delays calibrated >> dvisampler1: phase init OK >> dvisampler1: ph: 0 0 0 // charsync:000 [0 0 0] // WER: 0 0 0 // >> chansync:0 // res:0x0 > > Does it keep printing that (it should repeat at ~1Hz), or does it go > into the "disconnected" state immediately after?
It goes into disconnected state immediately after. Basically screen is flooded with these messages. > You should not have the "IDELAY busy timeout" messages, and the numbers > should be non-zero. Also WER=0 means either no transmission errors > (which is unlikely since the delay calibration failed) or no data at all > (signal lines completely idle). Have you checked the TMDS signals for > short circuits, possibly coming from the TVS solders? I've just did a quick check, and these lines seem to be OK, but I'll check it again. > >> With the ports01 bistream console output freezes soon after loading netboot >> firmware, >> for example during >> read: 3008Mbps write: 0Mbps all: 3008Mbps >> or >> waiting for LOCKED...ok >> and LED2 stops blinking. > > This is weird... Don't you see any other messages before the freeze? No, it's just that it freezes suddenly. I've checked this with another board and I have the same symptoms. It even freezes much sooner, always after 'Executing booted program.' line. > > Sebastien > _______________________________________________ Devel mailing list Devel@lists.milkymist.org https://ssl.serverraum.org/lists/listinfo/devel