Thank you for your contribution! Sashiko AI review found 1 potential
issue to consider:
- [High] arm64: dts: rockchip: missing resets in rk3576 NPU power-domain
  nodes
--

commit 4129f134d43a1e4e19c937117eb7565caa3c233d
Author: Jiaxing Hu <[email protected]>

arm64: dts: rockchip: add NPU (RKNN) nodes to rk3576

This commit adds the two RK3576 NPU core nodes and their IOMMU nodes to
rk3576.dtsi, and labels the NPU power domain node.

> diff --git a/arch/arm64/boot/dts/rockchip/rk3576.dtsi 
> b/arch/arm64/boot/dts/rockchip/rk3576.dtsi
> index 7828736bf9ac0..6ff95066d4701 100644
> --- a/arch/arm64/boot/dts/rockchip/rk3576.dtsi
> +++ b/arch/arm64/boot/dts/rockchip/rk3576.dtsi
> @@ -1131,7 +1131,7 @@ power: power-controller {
>                               #address-cells = <1>;
>                               #size-cells = <0>;
>  
> -                             power-domain@RK3576_PD_NPU {
> +                             pd_npu: power-domain@RK3576_PD_NPU {
>                                       reg = <RK3576_PD_NPU>;
>                                       #power-domain-cells = <1>;
>                                       #address-cells = <1>;
> @@ -1350,6 +1350,74 @@ power-domain@RK3576_PD_VO1 {
>                       };
>               };
>  
> +             rknn_core_0: npu@27700000 {
> +                     compatible = "rockchip,rk3576-rknn-core";
> +                     reg = <0x0 0x27700000 0x0 0x1000>,
> +                           <0x0 0x27701000 0x0 0x1000>,
> +                           <0x0 0x27703000 0x0 0x1000>;
> +                     reg-names = "pc", "cna", "core";
> +                     interrupts = <GIC_SPI 247 IRQ_TYPE_LEVEL_HIGH>;
> +                     clocks = <&cru ACLK_RKNN0>, <&cru HCLK_RKNN_ROOT>,
> +                              <&cru CLK_RKNN_DSU0>, <&cru PCLK_NPUTOP_ROOT>,
> +                              <&cru ACLK_RKNN_CBUF>, <&cru HCLK_RKNN_CBUF>;
> +                     clock-names = "aclk", "hclk", "npu", "pclk",
> +                                   "aclk_cbuf", "hclk_cbuf";
> +                     assigned-clocks = <&cru CLK_RKNN_DSU0>;
> +                     assigned-clock-rates = <594000000>;
> +                     resets = <&cru SRST_A_RKNN0>;
> +                     reset-names = "srst_a";
> +                     power-domains = <&power RK3576_PD_NPU0>;
> +                     iommus = <&rknn_mmu_0>;
> +                     status = "disabled";
> +             };

[Severity: High]
Are the power-domain@RK3576_PD_NPU0 and power-domain@RK3576_PD_NPU1 nodes
missing their resets properties (such as SRST_A_RKNN0_BIU and
SRST_A_RKNN1_BIU)?

40f898ca63cc ("pmdomain: rockchip: cycle an optional power-domain reset on
power-on") and commit "accel/rocket: let the core suspend after a reset"
rely on rockchip_pd_power() pulsing pd->reset when powering on the RK3576
NPU domains, both to clear the undefined bus interface state before QoS
and register accesses and to recover the IOMMU after a job timeout reset.
However, none of the RK3576 NPU power-domain nodes in rk3576.dtsi specify
a resets property, so pd->reset remains NULL and the bus interface reset
is never cycled:

arch/arm64/boot/dts/rockchip/rk3576.dtsi:
                                                power-domain@RK3576_PD_NPU0 {
                                                        reg = <RK3576_PD_NPU0>;
                                                        clocks = <&cru 
HCLK_RKNN_ROOT>,
                                                                 <&cru 
ACLK_RKNN0>;
                                                        pm_qos = <&qos_npu_m0>;
                                                        #power-domain-cells = 
<0>;
                                                };
                                                power-domain@RK3576_PD_NPU1 {
                                                        reg = <RK3576_PD_NPU1>;
                                                        clocks = <&cru 
HCLK_RKNN_ROOT>,
                                                                 <&cru 
ACLK_RKNN1>;
                                                        pm_qos = <&qos_npu_m1>;
                                                        #power-domain-cells = 
<0>;
                                                };

-- 
Sashiko AI review ยท 
https://sashiko.dev/#/patchset/[email protected]?part=11

Reply via email to