Tim:

Install a scrap resistor lead or piece of solid hookup wire from pin 1 to pin 3 on J9 and J10 and install a 103 Cap from pin 7 to pin 12 of J 11 and you will be back to what you had before... I would bet you have a problem on the SSB board. I had this on one SSB generator and it was either RFC1 or RFC2 that was shorting out to the crystal housing.

73
Jim Younce K4ZM