I was experiencing some erratic behavior, could have been a power
interruption issue.  I reloaded the firmwar; fixed! ( I have 2 sensors as
well, one high power HF and the VHF.)

Bill
K9YEQ


-----Original Message-----
From: elecraft-boun...@mailman.qth.net
[mailto:elecraft-boun...@mailman.qth.net] On Behalf Of K5WA


My W2 has a pair of 2 KW sensors which I run in the automatic sensor
switching mode.  This way, I don't have to flip any switches as I alternate
between each rig of my SO2R setup.  I am seeing erratic readings in the
automatic sensor switching mode that I am not seeing if I manually throw the
sensor switch to S1 or S2.  From this result, I am concluding that my sensor
hook up is RF sound and the fault must be in the automatic switching
algorithm of the W2.  I get the same erratic readings on the W2 as well as
the W2 software interface application.