Let's end this thread at this time.

73,

Eric
---
www.elecraft.com

On 8/6/2012 1:43 PM, Don Wilhelm wrote:
> The thing that matters is the voltage reduction under load.
> "IR" is correct for the voltage reduction.
> "I squared R" would represent the power reduction from the power panel
> to the shack.
>
> 73,
> Don W3FPR
>
> On 8/6/2012 2:59 PM, Monty Shultes wrote:
>> Actually it's "I-squared R drop", and a 1/2 reduction in current results in 
>> a 75% loss reduction.
>> Monty K2DLJ
>>
>>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html