Hi Martin, The power ramp up is normal behavior. The K2 uses requested power control (Page 92, "Requested vs. Actual Power:" paragraph)
With a per band set value (Page 111, "Microcontroller" paragraph, "ALC, which is used on CW to maintain the user-specified power level across all bands.") When changing bands, the output power is sampled by the microcontroller resulting with a change in the transmitter ALC to increase power. The ALC action requires a few dits or TUNE to complete. John KN5L K2 #7212 On 06/17/2018 01:43 AM, Martin Sole wrote: > After a band change the first dit, or two, is not at full power. > There seems to be an initial ramp up after which all is good and I don't > see any fluctuation in power. Supply is 13.5 volts when producing full > power, about 13.9 with just the receiver running. Full power current on > 28Mhz is showing on the display as 2.66A. I can see the ramp up on the > bar graph, it shows one bar for the first 3-4 dots then ramps up to all > 10 bars. I have confirmed the same with an external power meter. > Anything I can do about this? ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com