On Wed, 21 Apr 2010 11:27 -0700, "dave" <dengv...@charter.net> wrote:
> 
> Taking this a half-step further ...
>       a. hold position on master side of gantry
>       b. while monitoring a strain gage on the cross member minimize strain. 
>       c. sync sides
>       d. home using master side.
> Not easy but it makes sense to me. :-)
> Of course, a lot of things that make sense to me don't to other
> people. ;-)
> You have to really serious about the end result to do it this way. :-)
> 
> Dave
> 

Actually, the real goal isn't minimizing strain, it is ensuring that
the Y axis is 90 degrees to X.  Hopefully that is at or near the minimum
strain point, but axis squareness is really the critical parameter.

John Kasunich
-- 
  John Kasunich
  jmkasun...@fastmail.fm


------------------------------------------------------------------------------