Some time ago, I have written a small component which pulses at
machine-start if last lubrication was a configurable time away. Next
pulse is done if the way the machine has made in sum of moving of the
three axis hits a configurable limit (or even if the last lubrication is
too long ago again).
I guess two little components written in my poor c (one for saving the
way-values on exit, the other for calculating/shooting next lubrication
by time) the rest (way-calculation) is done in simple HAL.
If interested i can search for it.
Greets.
Am 21.11.2022 um 22:14 schrieb Jon Elson:
Hello, all,
I need a hal component for a lube pump. What I am looking for is more
like a one-shot than the existing timedelay component.
timedelay seems to be able to delay the start or the end of a signal,
but output will follow the input after the delays occur. I wanted a
component that would trigger for a set time after a trigger (or
LinuxCNC starting) and then, I could or it with the spindle enables.
This would ensure the lube pump starts immediately when LCNC starts,
and then run whenever the spindle is on. Anybody know a better way to
do this?
Thanks,
Jon